GRPABH=0, ADTRADEN=0, GRPDTE=0, ADTRAUEN=0, GRP=00, ADTRBDEN=0, ADTRBUEN=0, GRPABL=0
General PWM Timer Interrupt Output Setting Register
ADTRAUEN | GTADTRA Compare Match (Up-Counting) A/D Converter Start Request Interrupt Enable 0 (0): Disable A/D converter start request 1 (1): Enable A/D converter start request. |
ADTRADEN | GTADTRA Compare Match (Down-Counting) A/D Converter Start Request Interrupt Enable 0 (0): Disable A/D converter start request 1 (1): Enable A/D converter start request. |
ADTRBUEN | GTADTRB Compare Match (Up-Counting) A/D Converter Start Request Interrupt Enable 0 (0): Disable A/D converter start request 1 (1): Enable A/D converter start request. |
ADTRBDEN | GTADTRB Compare Match (Down-Counting) A/D Converter Start Request Interrupt Enable 0 (0): Disable A/D converter start request 1 (1): Enable A/D converter start request. |
GRP | Output Disable Source Select 0 (00): Select Group A output disable request 1 (01): Select Group B output disable request 2 (10): Select Group C output disable request 3 (11): Select Group D output disable request. |
GRPDTE | Dead Time Error Output Disable Request Enable 0 (0): Disable dead time error output disable request 1 (1): Enable dead time error output disable request |
GRPABH | Same Time Output Level High Disable Request Enable 0 (0): Disable same time output level high disable request 1 (1): Enable same time output level high disable request |
GRPABL | Same Time Output Level Low Disable Request Enable 0 (0): Disable same time output level low disable request 1 (1): Enable same time output level low disable request |